Tests were conducted on a 1:25-scale model of the filling and emptying systems of the existing 600- by 110-ft lock of the McAlpine project. These tests were concerned with whether structurally feasible modifications of the systems would result in decreased turbulence and hawser stresses and thus permit faster filling and emptying of the lock. (Author)


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Modernization of Filling and Emptying System, Existing McAlpine Lock (Old No. 41), Ohio River, Louisville, Kentucky; Hydraulic Model Investigation


    Contributors:
    J. H. Ables (author) / T. E. Murphy (author)

    Publication date :

    1967


    Size :

    56 pages


    Type of media :

    Report


    Type of material :

    No indication


    Language :

    English








    Filling and Emptying System, Dardanelle Lock, Arkansas River: Hydraulic Model Investigation

    Ables, Jackson H. Jr. / Boyd, Marden B. / United States. Army. Corps of Engineers. Los Angeles District. | HENRY – Federal Waterways Engineering and Research Institute (BAW) | 1969