On road vibration tests on a commercial vehicle cooling package are described and are the basis of a hydraulic rig desined to test package service life in a period of a few hours. Road test results are summarised and show a major vibration mode of plus/minus 1 g at 2 Hz. The rig design is described in outline and comparison is made of rig and road test vibrating patterns. Using the fatigue characteristics of the aluminium from which the charge air cooler is manufactured a means of making service life predictions for the cooling package is proposed.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Vibration testing of commercial vehicle cooling packages


    Additional title:

    Schwingungstest der Ladeluft-Kuehlanlagen fuer Nutzfahrzeuge


    Contributors:
    Bonyad, M.A. (author) / Phillips, B.D. (author) / Wilcock, D. (author)


    Publication date :

    1989


    Size :

    6 Seiten, 6 Bilder, 1 Quelle


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English