The paper describes the planning and installation of an offshore platform piled foundation in hard, overconsolidated clay, located north of the sixtieth parallel in the British Sector of the North Sea. The successful installation of the piles for the steel jacket platform in the Heather field is used as an illustrative example throughout the paper. Engineering considerations necessary for a successful installation are outlined starting from site selection and carried through the final comparison between pile capacity, pile driveability and pile driving experience. (Kursetz)


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Installing a piled foundation in hard, overconsolidated North Sea clay for the Heather platform


    Additional title:

    Installierung der Pfeilerfundamente im harten, ueberverdichteten Lehm des Nordseebodens bei der Plattform des Heather-Sektors


    Contributors:


    Publication date :

    1978


    Size :

    8 Seiten, 9 Bilder, 1 Tabelle, 10 Quellen


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English





    Geotechnical Behavior of Overconsolidated Surficial Clay Crusts

    Lutenegger, Alan J. | Online Contents | 1995


    Optimizing the Unconnected Piled Raft Foundation for Soft Clay Soils: Numerical Study