A six-axis femoral load cell was designed, fabricated, calibrated and tested in an ATD upper leg. It has linear characteristics with adequate output and dynamic response. Its output compared well with that of load cells mounted behind a knee bolster which was impacted by an ATD instrumented with this load cell. Although the axial load was found to be well below the present limit of FMVSS208, the bending moments were found to be high. A conservative tolerance limit for axial load should be considered and cadaver data are required.
Femoral Loads Measured by a Six-Axis Load Cell
Sae Technical Papers
23rd Stapp Car Crash Conference ; 1979
1979-02-01
Conference paper
English