Methane-filled heat pipes have been developed and qualified for the SCIAMACHY thermal bus assembly. The heat pipes provide an efficient heat transfer in the temperature range 100-160 K. Extensive qualification testing has been performed. The thermal bus assembly is part of the Thermal Bus Unit (TBU) of the SCIAMACHY Radiant Cooler.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Design and Qualification of Methane Filled Heat Pipes for the SCIAMACHY Radiant Cooler


    Additional title:

    Sae Technical Papers


    Contributors:
    Hauser, A. (author) / Aalders, B. G. M. (author) / Hauser, J. (author)

    Conference:

    International Conference On Environmental Systems ; 1997



    Publication date :

    1997-07-01




    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Design and qualification of methane-filled heat pipes for the SCIAMACHY radiant cooler

    Hauser, J. / European Space Agency | British Library Conference Proceedings | 1997



    Design and Qualification of Methane Filled Heat Pipes for the SCIAMACHY Radiant Cooler

    Hauser, J. / Hauser, A. / Aalders, B. G. M. et al. | British Library Conference Proceedings | 1997


    The Design, Development and Qualification of the SCIAMACHY Radiant Cooler

    Wigbers, I. J. G. | British Library Conference Proceedings | 1997


    The development of the SCIAMACHY radiant cooler

    Coesel, R. | British Library Online Contents | 1997