Methane-filled heat pipes have been developed and qualified for the SCIAMACHY thermal bus assembly. The heat pipes provide an efficient heat transfer in the temperature range 100-160 K. Extensive qualification testing has been performed. The thermal bus assembly is part of the Thermal Bus Unit (TBU) of the SCIAMACHY Radiant Cooler.
Design and Qualification of Methane Filled Heat Pipes for the SCIAMACHY Radiant Cooler
Sae Technical Papers
International Conference On Environmental Systems ; 1997
1997-07-01
Aufsatz (Konferenz)
Englisch
Design and qualification of methane-filled heat pipes for the SCIAMACHY radiant cooler
British Library Conference Proceedings | 1997
|Design and qualification of methane-filled heat pipes for the SCIAMACHY radiant cooler
British Library Online Contents | 1997
|The Design, Development and Qualification of the SCIAMACHY Radiant Cooler
British Library Conference Proceedings | 1997
|The development of the SCIAMACHY radiant cooler
British Library Online Contents | 1997
|The development of the SCIAMACHY radiant cooler
British Library Conference Proceedings | 1997
|