A series of vectoring axisymmetric ejector nozzles were designed and experimentally tested for internal performance and pumping characteristics at NASA-Langley Research Center. These ejector nozzles used convergent-divergent nozzles as the primary nozzles. The model geometric variables investigated were primary nozzle throat area, primary nozzle expansion ratio, effective ejector expansion ratio (ratio of shroud exit area to primary nozzle throat area), ratio of minimum ejector area to primary nozzle throat area, ratio of ejector upper slot height to lower slot height (measured on the vertical centerline), and thrust vector angle. The primary nozzle pressure ratio was varied from 2.0 to 10.0 depending upon primary nozzle throat area. The corrected ejector-to-primary nozzle weight-flow ratio was varied from 0 (no secondary flow) to approximately 0.21 (21 percent of primary weight-flow rate) depending on ejector nozzle configuration. In addition to the internal performance and pumping characteristics, static pressures were obtained on the shroud walls.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Internal performance characteristics of vectored axisymmetric ejector nozzles


    Contributors:

    Conference:

    AIAA, SAE, ASME, and ASEE, Joint Propulsion Conference and Exhibit ; 1993 ; Monterey, CA, United States


    Publication date :

    1993-06-01


    Type of media :

    Conference paper


    Type of material :

    No indication


    Language :

    English