Results are summarized herein of six test borings and four test pits made to investigate subsoil conditions at the location of the planned Huntington Station parking lost in Section C010g of Huntington Route, of the Washington Metropolitan Area Metro system. The site is bordered on the west by North Kings Highway and by Fort Drive on the south. The report contains geological sections through the parking lot, logs of the test borings and test pits, results of test performed on samples recovered and comments on anticipated design and construction problems.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Huntington Station Parking Lot Section CO10g, Huntington Route Subsurface Investigation


    Publication date :

    1982


    Size :

    26 pages


    Type of media :

    Report


    Type of material :

    No indication


    Language :

    English