Results of six borings made near the intersection of the proposed Huntington Route line with memorial Highway in Arlington, Virginia at the planned Arlington Cemetery Station are summarized. The report contains geological sections through the borings, logs of the borings and conclusions regarding subsoil properties. (Author)
Design Section C006e: Huntington Route. Subsurface Investigation, Arlington Cemetery Station
1972
20 pages
Report
No indication
English
Metropolitan Rail Transportation , Subway railways , District of Columbia , Railroad stations , Subsurface investigations , Foundations , Rock mechanics , Tunneling(Excavation) , Subsurface structures , Boring , Subsoil , Soil properties , Foundation engineering , Arlington Cemetery Station , Huntington Route , Design section C006e