The evaluation of a compact electrical-mechanical device for controlling the oxygen-nitrogen concentration of the atmosphere within an aerospace vehicle cabin simulator during a 2-man, 3-day test is described. Also described is a device used during the evaluation to program various rates of leakage of the atmosphere from the simulator so the response of the controller could be checked periodically. Data obtained reveal a capability for automatically controlling the oxygen-filler gas concentration in an aerospace vehicle cabin simulator over varying ranges of total cabin pressures. (Author)
Oxygen-Nitrogen Indicator-Controller and Space Cabin Outboard Leak Simulator
1964
2 pages
Report
No indication
English
NTIS | 1997
|Bacteriological studies of two-man space cabin simulator
NTRS | 1965
|Crew locomotion disturbances in a space cabin simulator
AIAA | 1969
|