Electric vehicle propulsion systems heavily depend on the reliable operation of permanent magnet synchronous motors (PMSMs). However, the susceptibility of PMSMs to electrical faults, particularly inter-turn short circuit (ITSC) faults, poses a significant threat to their overall reliability. With the purpose of enabling an immanent fault detection, we design a fault detection observer using the recently developed bi-limit-homogeneous sliding mode observer (BL-H SMO) technique. The BL-H SMO has the ability to offer zero error estimates within finite or fixed-time intervals even in the presence of unknown inputs, which is a distinctive advantage enhancing its efficacy in fault detection for PMSMs compared to standard Kalman filter schemes. These advantages are illustrated via a simulation study that validates and compares the proposed BL-H SMO’s performance with that of a Kalman filter.
A BL-Homogeneous Observer for Inter-Turn Short-Circuit Fault Detection in PMSMs
2024-08-21
2077369 byte
Conference paper
Electronic Resource
English
GAN-DRSN based Inter-turn Short Circuit Fault Diagnosis of PMSM
British Library Conference Proceedings | 2022
|Fault detection of motors inter-turn short circuit based on back propagation neural network
Automotive engineering | 2012
|