Failures of Welds 1089, 1090 and 1093 are described; 13 bend tests are included in report; tests are made on full-section rails on supports 48 in. apart and loaded at two places 6 in. on each side of weld line; results of bend tests are presented in table.
Investigation of failures of welded rails at University of Illinois