A preliminary report on the development of a system for monitoring the High Pressure Oxidizer Turbopump (HPOTP) of the Space Shuttle Main Energine (SSME) is presented. The system development will proceed by defining the degradation mechanisms of the turbopump, identifying those sensor measurments, both conventional and advanced, which can monitor these mechanisms, and determing the digiretal processing requirements for these measurements. Once the failures and associated measurements have been defined, an expert system will be nostic inferences about the condition and performance of the turbopump.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    An expert system approach to turbopump health monitoring


    Additional title:

    Expertensystem zur Ueberwachung des Zustands von Turbopumpen


    Contributors:
    Perry, J.G. (author) / Riechel, J.P. (author) / Norman, A.M. (author)

    Published in:

    AIAA-Papers ; Jul ; 1-6


    Publication date :

    1988


    Size :

    6 Seiten, 9 Bilder


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    An expert system approach to turbopump health monitoring

    PERRY, JOHN / RIECHEL, JAY / NORMAN, ARNIE et al. | AIAA | 1988


    Health Monitoring System of Turbopump