A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Verification of an analytic modeler for capillary pump loop thermal control systems


    Additional title:

    Ueberpruefung eines Modells fuer ein Waermeregelsystem mit Kapillarpumpenkreislauf


    Contributors:
    Schweickart, R.B. (author) / Neiswanger, L. (author) / Ku, J. (author)

    Published in:

    AIAA-Papers ; Jun ; 1-10


    Publication date :

    1987


    Size :

    10 Seiten, 15 Bilder, 1 Tabelle, 4 Quellen


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English