It is well known that the capacity of the positive electrodes of a lead/acid cell is affected greatly by various processes occurring during battery operation. Some of them result in an irreversible electrode degradation, while others are reversible. The authors discuss the reversible capacity decay for various types of electrodes and batteries. Qualitatively, the same effects are found with Plante, Faure and tubular electrodes. In situ measurements of the resistance of the active material using the Eloflux technique indicate that the effects are related to changes in the PbO2 structure. The experimental results are qualitatively explained by a recently developed model for the active-material structure
Reversible capacity decay of positive electrodes in lead/acid cells
Reversibler Kapazitätsverfall positiver Elektroden in Blei-Säure-Zellen
1991
14 Seiten, 15 Quellen
Article (Journal)
English
180Ahkg−1 specific capacity positive tubular electrodes for lead acid batteries
Online Contents | 2011
|How to understand the reversible capacity decay of the lead dioxide electrode
Online Contents | 1999
|Positive thin electrodes obtained from hydrothermally synthesized 4BS for lead-acid batteries
Online Contents | 2006
|Modeling lead-acid batteries that have positive electrodes containing hollow, glass microspheres
Online Contents | 1993
|