Field measurement of slug characteristics is conducted using gamma-densitometers in a 30-in gas-oil-water three-phase pipeline. The pipeline is quite flat with minor elevation changes. The gas, oil, and water flow rates are 66.859 sm³/s (204 mmscfd), 0.078 sm³/s (42,650 sbpd), and 0.151 sm³/s (82,000 sbpd), respectively. The operating pressure is relatively low, about 200 psia. The collected information includes slug frequency, slug length, translational velocity, and pressure. Liquid holdup in slug body and bubble region could also be estimated, but the uncertainty may be high, due to the way in which the gamma-densitometer is calibrated. The measured data indicates that only one large slug exists in the pipeline at a given time. After the previous large slug exits from the pipeline, a new large slug is formed. The explanation of this observation is investigated in this paper. The commercial multiphase flow simulator, OLGA®, is run and results arc compared to the field data. It is found that the OLGA model using the default delay constant significantly over-predicts slug frequency, and under-predicts slug length. After the model is tuned by changing the delay constant, much better agreement is achieved. This work shows that the use of the default value of delay constant may give less conservative results in terms of slug length and surge volume for large scale pipelines.
Measurement and simulation of slug flow in a large diameter three-phase pipeline
2013
13 Seiten, Bilder, Tabellen, 2 Quellen
Conference paper
English
Slug-flow behaviour clarified in large diameter pipeline study
Tema Archive | 1988
|Extended slug control for pipeline-riser systems
Tema Archive | 2005
|