As the operating status of the turbocharger is complex, nonlinear and requires high transient response, this paper studies a new control strategy which add self-adaption pilot control to the traditional PID control method, and adopts the static PI control or the dynamic PID control according to the control error, finally, carries out nonlinear transform on the output signal. The control strategy can both increase the respond speed of the turbocharger and avoid the over boost phenomenon. The experimental study is carried out under a 1.8 L turbocharged engine on the engine test bench and the automobile hub test bench, validates the feasibility and practicability of the control strategy.


    Access

    Access via TIB

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Study on Twin Modes Pilot Control of Turbocharger


    Contributors:
    Lin, Sicong (author) / Wu, Jian (author) / Zhang, Anwei (author) / Liu, Jujiang (author) / Hu, Jin (author)


    Publication date :

    2012


    Size :

    9 Seiten





    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Study on Twin Modes Pilot Control of Turbocharger

    Lin, Sicong / Wu, Jian / Zhang, Anwei et al. | Springer Verlag | 2012


    Study on Twin Modes Pilot Control of Turbocharger F2012-D01-012

    Lin, S. / Wu, J. / Zhang, A. et al. | British Library Conference Proceedings | 2013


    Study of twin modes pilot control of turbochargers

    Lin,S. / Wu,J. / Zhang,A. et al. | Automotive engineering | 2012


    Modelling of the twin-entry turbocharger turbine

    Katrasnik,T. / Univ.of Ljubljana,SI | Automotive engineering | 2007


    Modelling of the twin-entry turbocharger turbine

    Katrašnik, T. | Online Contents | 2007