A multi-leak detection system for pipelines is designed and tested. The multi-leak detection problem is solved using only sensors of flow and pressure at the extremes of the duct, and using the analytical redundancy given of these measurements. The Ieak detection design is based on a distributed pipeline model that is discretized in space and assumes a set of leaks distributed through the duct. Leak location is accomplished by evaluating the residuals of a bank of unknown input observers that are robust against one leak and sensitive to the rest. Simulation and experimental results are reported to demonstrate the effectiveness of the proposed approach when two leaks appear simultaneously.


    Access

    Access via TIB

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Multi-leak detection and isolation in fluid pipelines


    Additional title:

    Mehrfachleckerkennung und -ortung von flüssigkeitsführenden Rohrleitungen


    Contributors:
    Verde, C. (author)

    Published in:

    Publication date :

    2001


    Size :

    10 Seiten, 10 Bilder, 25 Quellen




    Type of media :

    Article (Journal)


    Type of material :

    Print


    Language :

    English