This paper presents a mathematical model for simulation of a diesel driven synchronous machine unit. This model is developed for the marine generator system, incorporating diesel engine, governor, synchronous generator and automatic excitation system. It is also shown, on the assumption that magnetic saturation arises in the generator principally from the resultant direct axis current, how the corresponding nonlinearity is included in the model. The transient performance of current, voltage, electromagnetic torque and angular velocity in short circuit condition or in various types of switching operational conditions may be predicted. A numerical example is given, and the computed results are presented.
Prediction of transient performance in a marine diesel driven generator system
Berechnung der transienten Leistung eines vom Schiffsdieselmotor angetriebenen Generatorsystems
1983
8 Seiten, 10 Bilder, 3 Tabellen, 7 Quellen
Conference paper
English
Diesel-driven energy-saving, marine generator developed
Tema Archive | 1980
Transient simulation of marine diesel engines
Automotive engineering | 1998
|Transient simulation of marine diesel engines
Tema Archive | 1998
|Product Report-Marine Diesel Generator From Yanmar
Online Contents | 1996
RBF NN based marine diesel engine generator modeling
Tema Archive | 2005
|