A nitrogen-cooled Michelson interferometer was fabricated using a unique flexural pivot mirror translation system which allows a proportionally large aperture and is ideally suited for operation at cryogenic temperatures. Cooling the entire interferometer yields a sensitivity sufficient to measure weak atmospheric emissions from an electron-gun induced artificial aurora. The spectral range 2.0 to 5.6 microm is scanned at a repetition rate of 1.8 seconds with an apodized resolution of 2 cm(sup-1). Piezoelectric elements in the fixed mirror mount allow realignment at cryogenic temperatures. Laser (sampling) and white light (absolute position) reference channels are run antiparallel to the main channel using the same optics. When launched aboard a Talos Castor rocket as part of the EXCEDE payload the interferometer maintained alignment within 20 percent of launch modulation efficiency.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Rocket-borne cryogenic Michelson interferometer


    Additional title:

    Raketengetragenes fluessig Stickstoff gekuehltes Michelson-Interferometer


    Contributors:
    Kemp, J.C. (author) / Huppi, R.J. (author)


    Publication date :

    1979


    Size :

    8 Seiten, 7 Bilder, 4 Quellen


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Rocket-borne cryogenic air samplers

    Denton, E. H. | NTRS | 1970


    The Nimbus 4 Michelson Interferometer

    R. A. Hanel / D. Rogers / B. Schlachman et al. | NTIS | 1970


    Multiple spacecraft Michelson stellar interferometer

    Stachnik, R. V. / Arnold, D. / Melroy, P. et al. | NTRS | 1984