This paper analyzes the magnetic field coupling from System Generated Electromagnetic Pulse (SGEMP) in terminal protection devices (TPD's) to non-interface or buried circuits of spacecraft electronics boxes. The analysis approach is outlined and results obtained from a computer based solution of the analysis are presented along with test data collected to empirically verify the analysis. Finally an example is provided in which the analysis results are used to calculate the energy coupled to a buried circuit so that a comparison of known device pulse burn out levels can be made. This technique provides an assessment of device susceptibility to the induced fields for representative circuit board trace layouts.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    SGEMP induced magnetic field coupling to buried circuits


    Additional title:

    Durch systemerzeugte EMP induzierte magnetische Feldkopplung zu geerdeten Schaltungen


    Contributors:


    Publication date :

    1985


    Size :

    5 Seiten, 7 Bilder, 3 Tabellen, 1 Quelle


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English