This paper contains a discussion of the comparison of analytical and experimental results of the dynamic response of a flat rectangular plate subjected to electro-impulse type deicing forces. Early attempts in this correlation have been hampered by the complex leading edge geometries of the airfoils tested to date. The lack of a suitable analytical model for a typical leading edge structure has prompted these preliminary investigations of simple geometries beginning with a flat plate and to be followed by a semi-cylindrical leading edge representation. The comparisons reported herein are thus limited to rectangular plate models. Project plans and icing tunnel results are given.
Electro-impulse deicing: Structural dynamic studies, icing tunnel tests and applications
Elektroimpuls-Einteisung: dynamische Strukturuntersuchungen. Vereisungstunneltests und Anwendungen
1984
5 Seiten, 9 Bilder, 2 Quellen
Conference paper
English
Tema Archive | 1988
|