The body of information presented in this paper is directed toward those individuals involved with handling hazardous materials, wheter in actual use of such chemicals, or in monitoring atmospheric emissions. Althoug specifically relating experience in the design and testing of phosgene emission control equipment, it attempts to establish general guidelines for effectively dealing with emissions of hazardous materials. The paper presents a technique for establishing process emissions at acceptably low levels to insure the health and safety of the general population as well as that of the process workers themselves. Methods, suitable for measuring phosgene at these low levels, have been investigated, and problems associated with such an investigation are discussed.


    Access

    Access via TIB

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    A caustic scrubber system for the control of phosgene emissions: Design, testing, and performance


    Additional title:

    Ein Laugenwaescher-System fuer die Begrenzung von Phosgenemissionen: Auslegung, Test und Kenngroessen


    Contributors:
    Kistner, S. (author) / Lillian, D. (author) / Ursillo, J. (author)


    Publication date :

    1978


    Size :

    4 Seiten, 2 Bilder, 2 Tabellen, 10 Quellen