Abstract A preliminary test of a compressor developed to compress superfluid 3He-4He mixture in a superfluid Joule-Thomson refrigerator has been conducted using 4He gas at 4.2 Kelvin. The results of this test and a description of the compressor design are presented in this paper.
Preliminary Performance of a Superfluid 3He -4He Compressor
Cryocoolers 12 ; 675-679
2003-01-01
5 pages
Article/Chapter (Book)
Electronic Resource
English
Preliminary Performance of a Superfluid ^3He-^4He Compressor
British Library Conference Proceedings | 2003
|STEP superfluid helium dewar performance
British Library Conference Proceedings | 1996
|HP compressor preliminary design
British Library Conference Proceedings | 2013
|Preliminary Experimental Results Using a Three-Stage Superfluid Stirling Refrigerator
British Library Conference Proceedings | 2003
|Preliminary Experimental Results Using a Three-Stage Superfluid Stirling Refrigerator
Springer Verlag | 2003
|