This work is intended to study and compare the performance of 15 kW three-phase reluctance synchronous motor, ferrite-assisted reluctance synchronous motor along with induction motor for centrifugal pump application used in fluid flow application of food and process industries in terms of torque density, efficiency, volume and thermal behavior. The electromagnetic and thermal behavior is predicted by MagNet and ThermNet FEA software. The work involves an initial prototyping and validation of predicted performance by means of a motor–pump system coupled to tank setup. Also, this procedure is initiated through establishment of operating points by matching the speed–torque characteristics of motors and pump system load.
Electromagnetic Performance and Thermal Analysis of Reluctance Synchronous and Magnet-Assisted Reluctance Synchronous Motors for Industrial Pump Application
Springer Proceed. in Energy
2021-05-08
12 pages
Article/Chapter (Book)
Electronic Resource
English
Permanent magnet, reluctance, and self-synchronous motors
TIBKAT | 1993
|A permanent magnet-assisted synchronous reluctance motor
Online Contents | 2003
|Sensorless control of synchronous reluctance motors
IEEE | 2017
|