In other work by these authors1 it was experimentally found that with a helium circulation rate of over 0.5 1/min internal to a cooler, the outgassing process inside the cryocooler is as intensive as it is under a high vacuum. During 20 years of theoretical and experimental outgassing studies2,3,7 we have also found that the outgassing rate in the diffusion mode is quite reproducible. Using these results, an accelerated cryocooler test method for cryodeposit failures has been developed and experimentally validated. The proposed approach allows the required test time to be reduced by a factor of 20 to 50.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Accelerated Cryocooler Life Tests for Cryodeposit Failures


    Contributors:
    Ross, R. G. (editor) / Getmanets, V.F. (author) / Zhun, G.G. (author) / Stears, H. (author)

    Published in:

    Cryocoolers 10 ; Chapter : 87 ; 743-751


    Publication date :

    2002-01-01


    Size :

    9 pages




    Type of media :

    Article/Chapter (Book)


    Type of material :

    Electronic Resource


    Language :

    English




    Accelerated Cryocooler Life Tests for Cryodeposit Failures