Abstract An energy-based semi-active control strategy is presented to reduce structural vibration. The equation of motion is derived from a structure-TLCD coupled system. Material and geometrical nonlinearities have been considered in the 3D irregular system. The rigid floors and plan irregularity in the system are assumed. An on-off control orifice is located in the middle of the U-shaped tube TLCD system. The El-Centro 1940 earthquake excitation record is employed to train the algorithm, and two other earthquake excitations are applied to evaluate the performance of the proposed method. The results show that the RMS values of displacement and acceleration responses of the structure reduced significantly under seismic excitations.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Response control of irregular structures using structure-TLCD coupled system under seismic excitations


    Contributors:

    Published in:

    Publication date :

    2014-11-21


    Size :

    10 pages




    Type of media :

    Article (Journal)


    Type of material :

    Electronic Resource


    Language :

    English





    Stochastic seismic performance of TLCD for the passive control of structures

    Han, Bong Koo / Won, Young Jun | Springer Verlag | 1998



    Performance Assessment of Coupled Dam-Foundation System for Recorded Seismic Excitations

    Tidke, Aniket R. / Adhikary, Shrabony | Springer Verlag | 2021


    Peak earthquake response of structures under multi-component excitations

    Song, J. / Liang, Z. / Chu, Y.-L. et al. | British Library Online Contents | 2007