A spacecraft was instrumented with four temperature controlled quartz crystal microbalance (TQCM) contamination detectors. One TQCM, located inside the vehicle, recorded contaminant deposition that was orders of magnitude higher than did the three TQCMs located in various positions outside the vehicle. The deposition rate on the interior TQCM varied with the temperatures of interior spacecraft cavity surfaces. In particular, there is clear evidence of condensation on these surfaces and re-evaporation from these surfaces by previously outgassed contaminant molecules. The e-folding time constants of the deposition on two of the exterior TQCMs held at -50 degree(s)C are approximately 1.4 years, with extrapolated final equivalent thickness of the deposition in the 20 - 25 nm (200 - 250 angstroms) range. The third exterior TQCM, which has a significant field of view of a segmented thermal blanket, collected contamination at a greater rate. The data enable the ranking of the several contamination transport mechanisms at work and the drawing of general recommendations for spacecraft design.
Flight measurement of molecular contaminant deposition
Optical System Contamination: Effects, Measurements, and Control IV ; 1994 ; San Diego,CA,United States
Proc. SPIE ; 2261
1994-10-19
Conference paper
Electronic Resource
English
Flight measurement of molecular contaminant environment
AIAA | 1995
|Flight measurement of molecular contaminant environment
British Library Online Contents | 1994
|MSX Satellite Flight Measurements of Contaminant Deposition on a CQCM and on TQCMs
British Library Conference Proceedings | 1997
|