The use of a corrosion inhibited arsenical brass alloy for copper/brass radiator tubes has been identified as an effective means to protect the radiator tubes from external dezincification attack, which is generally caused by an exposure to excessive road salts in the regions such as Montreal and Toronto in Canada. Laboratory test methods, their results and field data verifying improved radiator life are presented.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Dezincification Corrosion and Its Prevention for Copper/Brass Radiators


    Additional title:

    Sae Technical Papers


    Contributors:

    Conference:

    SAE Automotive Corrosion and Prevention Conference and Exposition ; 1983



    Publication date :

    1983-12-05




    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Dezincification Corrosion and Its Prevention for Copper/Brass Radiators

    Park,K.H. / Ford Motor,US | Automotive engineering | 1983


    Corrosion of Copper/Brass radiators - corrosion mechanisms - prevention actions

    Ainali,M. / Beal,R.E. / Sundberg,R. et al. | Automotive engineering | 1992


    Corrosion of Copper/Brass Radiators - Corrosion Mechanisms - Prevention Actions

    Wickman, Lena / Ainali, Markku / Sundberg, Rolf et al. | SAE Technical Papers | 1992


    Recycling of copper/brass radiators

    Sundberg,R. / Outokumpu Copper,US | Automotive engineering | 1996


    Recycling of Copper/Brass Radiators

    Sundberg, Rolf | SAE Technical Papers | 1996