This procedure is applicable to modes from 500 and 13,000 Hz. The parameters measured with this procedure are defined as the damping factor, ξ for first nine vibration modes of the beam. The measurement will be done in free-free conditions and with temperature. Damping is an important characteristic of a brake insulator. There is currently no recognized standard for measuring this quantity. This Recommended Practice covers the measurement of the damping properties of a brake insulator bonded to a steel beam.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Brake Insulator Damping Measurement Procedure


    Publication date :

    2016-04-20



    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English






    The Development of a Brake Insulator Damping Measurement Procedure

    Denys, Eric / Thompson, James K. | SAE Technical Papers | 2010


    The Development of a Global Brake Insulator Damping Measurement Procedure

    Denys, E. | British Library Conference Proceedings | 2011