Quantitative planar laser-induced fluorescence measurements of fuel/air mixing in engines are usually based on the use of fluorescence tracers. The strength of the signals often depends on temperature, pressure and mixture composition. This complicates a quantitative analysis. The use of a small-bore optical engine for fundamental studies of absorption and fluorescence properties of fluorescence tracers is described. The temperature, pressure and composition dependence of the spectra of toluene, acetone, 3-pentanone, and biacetyl are examined under motored conditions to extend the experimental data base for the development of comprehensive models that predict the strength of fluorescence signals for a given condition.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Absorption and Fluorescence Data of Acetone, 3-Pentanone, Biacetyl, and Toluene at Engine-Specific Combinations of Temperature and Pressure


    Additional title:

    Sae Technical Papers


    Contributors:

    Conference:

    2005 SAE Brasil Fuels & Lubricants Meeting ; 2005



    Publication date :

    2005-05-11




    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English


    Keywords :