In order to assess the effect of PEM-FC poisoning resulting from impurities on PEM-FC performance, this paper investigated contents as follows; · Estimation for composition and concentration of impurities contained within hydrogen fuel and air. · The prediction of poisoning extent and proposal of assessment index for impurity poisoning. · Allowable mixing concentration of impurities for the standard H2 fuel. The analysis and experiment are conducted under 70 °C and 1 bar for operating temperature and pressure. PEM-FC with Pt and Pt-Ru type catalytic-electrode was used. It was observed that: · CO poisoning was reversible but H2S and SO2 poisonings were irreversible. It was also confirmed that sulfur compounds poisoning was very strong. On the contrary, poisoning of HCHO and CH4 etc. was slight or negligible. · In case of cathode electrode, the effect of NO2 and SO2 poisoning on PEM-FC performance was severe when CO poisoning was negligible.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    A Study Regarding Effects of Proton Exchange Membrane Fuel Cell Poisoning Due to Impurities on Fuel Cell Performance


    Additional title:

    Sae Technical Papers


    Contributors:

    Conference:

    SAE World Congress & Exhibition ; 2007



    Publication date :

    2007-04-16




    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English


    Keywords :




    Proton Exchange Membrane Fuel Cell Performance Modeling

    Marr, C. / Li, X. / Canadian Society for Mechanical Engineering | British Library Conference Proceedings | 1998