Side impact tests were conducted on the EUROSID and SID to assess their biofidelity compared to the response requirements of the international Standards Organization. The body regions evaluated were the head, neck, thorax, shoulder, abdomen, and pelvis. Test conditions and data normalization procedures are outlined in the report. Data plots are given which compare the impact response of each dummy to the ISO requirements. The EUROSID gave humanlike responses for most tests involving padded surface impacts, but its responses were not humanlike for rigid surface impacts. Overall, the EUROSID responses were more humanlike than the responses of the SID.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Comparison of the EUROSID and SID Impact Responses to the Response Corridors of the International Standards Organization


    Additional title:

    Sae Technical Papers



    Conference:

    SAE International Congress and Exposition ; 1989



    Publication date :

    1989-02-01




    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English





    Comparison of EUROSID and cadaver responses in side impacts

    Janssen,E.G. / Wismans,J. / Coo,P.J.de | Automotive engineering | 1989


    The EUROSID side impact dummy

    Automotive engineering | 1985


    Evaluation of Impact Responses of the EUROSID-1 and BIOSID

    Harigae, T. / Ohsaki, K. / Ohmae, H. et al. | British Library Conference Proceedings | 1991


    Report on EUROSID 1989

    Roberts, A. | British Library Conference Proceedings | 1996