A need for low-speed, high Reynolds number test capabilities has been identified for the design and development of advanced subsonic transport high-lift systems. In support of this need, multiple investigations have been conducted in the National Transonic Facility (NTF) at the NASA Langley Research Center to develop a semi-span testing capability that will provide the low-speed, flight Reynolds number data currently unattainable using conventional sting-mounted, full-span models. Although a semi-span testing capability will effectively double the Reynolds number capability over full-span models, it does come at the expense of contending with the issue of the interaction of the flow over the model with the windtunnel wall boundary layer. To address this issue the size and shape of the semi-span model mounting geometry have been investigated, and the results are presented herein. The cryogenic operating environment of the NTF produced another semi-span test technique issue in that varying thermal gradients have developed on the large semi-span balance. The suspected cause of these thermal gradients and methods to eliminate them are presented. Data are also presented that demonstrate the successful elimination of these varying thermal gradients during cryogenic operations.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Development of a Semi-Span Test Capability at the National Transonic Facility


    Contributors:

    Conference:

    Aerospace Sciences ; 2001 ; Reno, NV, United States


    Publication date :

    2001-01-01


    Type of media :

    Preprint


    Type of material :

    No indication


    Language :

    English




    Development of a semi-span test capability at the National Transonic Facility

    Gatlin, G. / Parker, P. / Owens, Jr., L. | AIAA | 2001


    Development of a Semi-Span Test Capability at the National Transonic Facility (Invited)

    Gatlin, G. M. / Parker, P. A. / Owens, L. R. et al. | British Library Conference Proceedings | 2001


    Recent Improvements in Semi-Span Testing at the National Transonic Facility (Invited)

    Gatlin, G. M. / Tomek, W. G. / Payne, F. M. et al. | NTRS | 2006


    Recent Improvements in Semi-Span Testing at the National Transonic Facility (Invited)

    G. M. Gatlin / W. G. Tomek / F. M. Payne et al. | NTIS | 2006


    Recent Improvements in Semi-Span Testing at the National Transonic Facility (Invited)

    Gatlin, Gregory M. / Tomek, William G. / Payne, Francis M. et al. | NTRS | 2006