Clean surface assured for more sensitive inspection with fluorescent penetrant dye. Simple procedure devised to ensure visible (red) penetrant dye used to identify flaws in welded surface completely removed from surface. Consists in applying reversible penetrant developer to surface to be inspected.
Verifying Removal Of Red Penetrant Dye From Inspected Welds
NASA Tech Briefs ; 20 , 3
1996-03-01
Miscellaneous
No indication
English
Verifying Removal of Red Penetrant Dye From Inspected Welds
Online Contents | 1996
Tema Archive | 1992
Verifying root fusion in electron-beam welds
NTRS | 1980
|Aircraft engine castings inspected faster