Louvers configured to accept rather than reject heat. Visually identical to those that open with increasing temperature, only difference being that bimetallic spring actuates open and closing mounted backwards to obtain reverse function.
Reverse-Acting Temperature-Control Louvers
NASA Tech Briefs ; 19 , 12
1995-12-01
Miscellaneous
No indication
English
Reverse-Acting Temperature-Control Louvers
Online Contents | 1995
Louvers for spacecraft temperature control
AIAA | 1987
|Analysis of movable louvers for temperature control
Engineering Index Backfile | 1964
|Analysis of movable louvers for temperature control
AIAA | 1964
|MEMS Louvers for Thermal Control
British Library Conference Proceedings | 1999
|