This paper presents the first results in an assessment of the strength, stiffness, and damage tolerance of stiffened wing and fuselage subcomponents. Under this NASA funded program, 10 large wing and fuselage panels, variously fabricated by automated tow placement and dry-stitched preform/resin transfer molding, are to be tested. The first test of an automated tow placement six-longeron fuselage panel under shear load was completed successfully. Using NASTRAN finite-element analysis the stiffness of the panel in the linear range prior to buckling was predicted within 3.5 percent. A nonlinear analysis predicted the buckling load within 10 percent and final failure load within 6 percent. The first test of a resin transfer molding six-stringer wing panel under compression was also completed. The panel failed unexpectedly in buckling because of inadequate supporting structure. The average strain was 0.43 percent with a line load of 20.3 kips per inch of width. This strain still exceeds the design allowable strains. Also, the stringers did not debond before failure, which is in contrast to the general behavior of unstitched panels.
Test results from large wing and fuselage panels
1993-01-01
Conference paper
No indication
English
Test Results from Large Wing and Fuselage Panels
NTIS | 1993
|Test Results From Large Wing and Fuselage Panels
British Library Conference Proceedings | 1992
|Wing-fuselage flutter of large aeroplanes
TIBKAT | 1953
|Adhesive bonding of large fuselage panels
Emerald Group Publishing | 1972