Experiments with liquid nitrogen and liquid hydrogen is styrofoam-insulated tanks have indicated good agreement between measured and calculated heat-leak rates when the insulation was formed from a single block of material. In a large tank installation where the insulation was applied in sections without sealing the joints, the measured heat leak was about 2 and 1/2 times the calculated value.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Experimental study of foam-insulated liquified-gas tanks


    Contributors:

    Publication date :

    1957-01-18