Initial results of the integrated AR POST conducted by Boeing at Marshall Space Flight Center in 1992 are presented. The three baselined ECLSS Man Tended Capability AR assemblies were integrated and operated in a closed door chamber in which the internal atmosphere was monitored. The test provides a prerequisite checkout of the AR subsystem in preparation for longer duration tests in which the AR subsystem will be integrated with the Water Recovery Management subsystem. The integrated AR POST will serve as an early test bed to evaluate the integration of the space station ECLSS AR subsystem during design maturation.
Initial accomplishments of the Environmental Control and Life Support System (ECLSS) atmosphere revitalization (AR) predevelopment operational system test (POST) for the Space Station Freedom (SSF)
SAE, International Conference on Environmental Systems ; 1992 ; Seattle, WA, United States
1992-07-01
Conference paper
No indication
English
Space Station Freedom Predevelopment Operational System Test (POST) Carbon Dioxide Removal Assembly
SAE Technical Papers | 1990
|Atmosphere Composition Monitor for Predevelopment Operational System Test
SAE Technical Papers | 1990
|