Report describes experiments conducted to determine whether, in vibration tests of truss structure, active structural members can be used to excite test vibrations yielding accurate data on vibrational modes of structure. Results indicate accuracies equal or exceed those obtained from external-excitation tests.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Vibration Testing Of Trusses By Use Of Active Members


    Contributors:

    Published in:

    Publication date :

    1992-06-01



    Type of media :

    Miscellaneous


    Type of material :

    No indication


    Language :

    English


    Keywords :


    Active Members Excite And Measure Vibrations In Trusses

    Kuo, Chin-Po / Chen, Gun-Shing / Wada, Ben K. | NTRS | 1993


    Dynamic Output and Structural Response Prediction for Active Members Integrated in Trusses

    Flint, E. / Rogers, C. / Liang, C. et al. | British Library Conference Proceedings | 1995


    Trusses stiffen Hupp frame, tying it to body members

    Denham, A.F. | Engineering Index Backfile | 1932


    Active Tendon Control of Large Trusses

    Preumont, A. / Achkire, Y. / Bossens, F. et al. | British Library Conference Proceedings | 1998


    Active Tendon Control of Large Trusses

    A. Preumont / Y. Achkire / F. Bossens | AIAA | 2000