The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA analysis of the EPD and C/RMS hardware initially generated 345 failure mode worksheets and identified 117 Potential Critical Items (PCIs) before starting the assessment process. These analysis results were compared to the proposed NASA Post 51-L baseline of 132 FMEAs and 66 CIL items.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Independent Orbiter Assessment (IOA): Assessment of the EPD and C/remote manipulator system FMEA/CIL


    Contributors:

    Publication date :

    1988-03-04


    Type of media :

    Report


    Type of material :

    No indication


    Language :

    English




    Independent Orbiter Assessment (IOA): Assessment of the remote manipulator system FMEA/CIL

    Tangorra, F. / Grasmeder, R. F. / Montgomery, A. D. | NTRS | 1988


    Independent Orbiter Assessment (IOA): FMEA/CIL assessment

    Hinsdale, L. W. / Swain, L. J. / Barnes, J. E. | NTRS | 1988


    Independent Orbiter Assessment (IOA): FMEA/CIL assessment

    Saiidi, Mo J. / Swain, L. J. / Compton, J. M. | NTRS | 1988