The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) images the ground with an instantaneous field of view (IFOV) of 1 mrad. The IFOV is scanned 30 deg from left to right to provide the cross-track dimension of the image, while the aircraft's motion provides the along-track dimension. The scanning frequency is 12 Hz, with a scan efficiency of 70 percent. The scan mirror has an effective diameter of 5.7 in, and its positional accuracy is a small fraction of a milliradian of the nominal position-time profile. Described are the design and performance of the scan drive mechanism. Tradeoffs among various approaches are discussed, and the reasons given for the selection of the cam drive.
AVIRIS scan drive design and performance
1987-11-15
Conference paper
No indication
English
AVIRIS scan drive design and performance
NTRS | 1988
|British Library Conference Proceedings | 1991
|Calibration of AVIRIS Digitized Data
British Library Conference Proceedings | 1991
|