To improve operational tolerances and mass, the H2 gas recombination design provisions of the Ni-H2 system were incorporated into the sealed Ni-Cd system. Produced is a cell design capable of operating on the H2 cycle versus the normal O2 cycle. Three test cells have now completed approximately 4,330 LEO (90 minute) cycles at 20 percent depth of discharge (DOD). Performance remains stable although one cell exhibited a temporary pressure anomaly.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Test summary for advanced H2 cycle NI-CD cell