Wires yield data on average strains over distances ranging from inches to many feet. Long constantan wires used to measure average strains over distances characteristic of vehicles or buildings. Connected in bridge circuit, wires measure strain accurately within 1 percent, and linearly, within 0.1 percent. Wires stretch as much as 0.15 percent and still return to zero residual strain after release.
Large Wire Strain Gauges
NASA Tech Briefs ; 11 , 3
1987-03-01
Miscellaneous
No indication
English
The physical characteristics of wire resistance strain gauges
TIBKAT | 1952
|Program Calibrates Strain Gauges
NTRS | 1991
|High-Temperature Resistance Strain Gauges
NTRS | 1994
|Shaft alignment using strain gauges
Tema Archive | 1981
|