The performance of NiCd batteries on the Viking Mars landers is discussed. During evaluation, three of the four batteries were maintained in the discharged state. Battery charge regimes and close-together, deep-discharge, reconditioning cycles to retard degradation of batteries are discussed. The effect of elevated temperatures during Martian summer on battery performance were also considered. Tabulated data for average battery capacity as a function of time are given. A design uplink to allow more frequent, greater depth of discharge reconditioning cycles was proposed.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Update: Viking Lander NiCd batteries. Year six


    Contributors:


    Publication date :

    1982-03-01


    Type of media :

    Conference paper


    Type of material :

    No indication


    Language :

    English




    Final Viking NiCd battery conditioning