Nine simplified analytic models based on average properties accurately predict heat rates for silicon/germanium thermoelectric generators. Solutions from simplified models were compared with those obtained using sophisticated numerical analysis. Maximum errors in calculated heat rate range from about 4 percent to about 0.2 percent. Models also used to calculate power delivered to load and thermodynamic efficiency.
Design Calculations for Thermoelectric Generators
NASA Tech Briefs ; 7 , 2
1983-05-01