Results of jet noise suppression tests conducted on a Rolls-Royce Viper 601 turbojet engine are reported. Seven exhaust nozzle configurations are tested, including two conical nozzles, two suppressor mixers, and three treated ejector configurations with different ejector inlets. Tests are conducted at the NASA Ames outdoor static test facility and the 40- by 80-ft wind tunnel facility at minimum tunnel flow velocity and normal flow velocities of 230 and 290 ft/sec. Near-field multiple sideline noise levels are projected to the far fields to compare far-field fixed microphone outdoor static noise levels, and wind tunnel near-field noise data are projected to the far field and flight distances to compare with noise levels recorded from an Hs-125 aircraft. Near-field outdoor noise data duplicate the far-field data recorded from fixed microphones within 2 PNdB, and the Douglas mechanical jet noise suppressor/treated ejector exhaust system achieves a noise reduction of 12 EPNdB relative to a conic reference nozzle at equal thrust in flight.
Jet noise results from static, wind tunnel, and flight tests of conical and mechanical suppressor nozzles
Aeroacoustics Conference ; 1981 ; Palo Alto, CA
1981-10-01
Conference paper
No indication
English