To make comparisons with experimental motion sickness susceptibility in Skylab missions, subjects were tested during free fall in parabolic flight and in ground-based simulation tests. They were rotated at 30 rpm in a rotating litter chair (RLC) with head fixed, head swiveling left-to-right, or with 90 degree forward and return head and body movements. Stressful accelerations similar to those in the Skylab RLC were generated only in the tests aloft, where subjects who made 'forward and return' movements (generating cross-coupled angular accelerations) were substantially more prone to motion sickness than those with either head fixed or head swiveling left-to-right. However, with head swiveling, susceptibility was slightly higher in the laboratory than aloft.