Sensor and associated microcomputer-based data acquisition unit can measure up to 1,024 unknown pressures at data rates as high as 10 kHz with maximum system inaccuracies of + or - 0.25 percent of full scale. System can be calibrated in place, making it easy to calibrate between runs for high cost or short run time wind tunnel testing.