An investigation to determine the effect of forward speed on the exhaust noise from a conical ejector nozzle and three suppressor nozzles mounted behind a J85 engine was performed in a 40- by 80-foot wind tunnel. The nozzles were tested at three engine power settings and at wind tunnel forward speeds up to 91 m/sec (300 ft/sec). In addition, outdoor static tests were conducted to determine (1) the differences between near field and far field measurements, (2) the effect of an airframe on the far field directivity of each nozzle, and (3) the relative suppression of each nozzle with respect to the baseline conical ejector nozzle. It was found that corrections to near field data are necessary to extrapolate to far field data and that the presence of the airframe changed the far field directivity as measured statically. The results show that the effect of forward speed was to reduce the noise from each nozzle more in the area of peak noise, but the change in forward quadrant noise was small or negligible. A comparison of wind tunnel data with available flight test data shows good agreement.
The effect of forward speed on J85 engine noise from suppressor nozzles as measured in the NASA-Ames 40- by 80-foot wind tunnel
1977-02-01
Miscellaneous
No indication
English